Mueller PyroPure WFI System

Mueller PyroPure WFI System

Description

Used Mueller PyroPure WFI System


Reliable, efficient system for pharmaceutical WFI production. Feedwater enters the first effect evaporator (heated by utility steam). Pure steam from each effect heats the next. Final pure steam from the last effect is condensed. Includes separation columns for droplet removal and conductivity monitoring for feedwater and final product.


WFI Output: Approximately 370 gallons per hour or 1,400 liters per hour


Includes:

  • Mueller MES 6040-5 WFI Still (5-effect Configuration)
  • Mueller Pyropure P7145 Pure Steam Generator (Capacity - Approx. 1,400 lb/hr or 635 kg/hr)
  • WFI Storage Tank


OEM Specification Sheet Attached


Available as a Complete System or Individual Components

Specifications

ManufacturerMueller
ConditionUsed
Stock Number1845-02
PSG Feedwater Pressure150 psig/Maximum of 1 ppm silica or total hardness. No chlorine, chlorides, or amines.
PSG Footprint Dimensions46.5" x 48" x 107" (depth x width x height) @ 2,350 lbs
WFI Still Required Steam Supply950 lbs/hr or 430 kg/hr
WFI Still Coolant Supply460 GPH or 1,740 LPH
WFI Still Approx Footprint Dimensions110" x 94" x 45" (H x W x D) @ 4,400 lbs