Mueller PyroPure WFI System
Featured

Mueller PyroPure WFI System
or
Call 1-800 LIKE NEW
Description
Used Mueller PyroPure WFI System
Reliable, efficient system for pharmaceutical WFI production. Feedwater enters the first effect evaporator (heated by utility steam). Pure steam from each effect heats the next. Final pure steam from the last effect is condensed. Includes separation columns for droplet removal and conductivity monitoring for feedwater and final product.
WFI Output: Approximately 370 gallons per hour or 1,400 liters per hour
Includes:
- Mueller MES 6040-5 WFI Still (5-effect Configuration)
- Mueller Pyropure P7145 Pure Steam Generator (Capacity - Approx. 1,400 lb/hr or 635 kg/hr)
- WFI Storage Tank
OEM Specification Sheet Attached
Available as a Complete System or Individual Components
Specifications
| Manufacturer | Mueller |
| Condition | Used |
| Stock Number | 1845-02 |
| PSG Feedwater Pressure | 150 psig/Maximum of 1 ppm silica or total hardness. No chlorine, chlorides, or amines. |
| PSG Footprint Dimensions | 46.5" x 48" x 107" (depth x width x height) @ 2,350 lbs |
| WFI Still Required Steam Supply | 950 lbs/hr or 430 kg/hr |
| WFI Still Coolant Supply | 460 GPH or 1,740 LPH |
| WFI Still Approx Footprint Dimensions | 110" x 94" x 45" (H x W x D) @ 4,400 lbs |